Shipboard Cables

Share:

Shipboard Cables

Beurau Veritas cables , Lloyd’s registered cables , Rina & ABS ships approval- Multicore Cables suitable for shipboard installations. Shipboard Cables

SH-PC-U – Unarmoured power & control shipboard cable – XLPE / SHF1 – 600/1000V

These Ships Approved SH-PC-U unarmoured power & control cables are suitable for shipboard use, they have a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-PC-A – Armoured power & control shipboard cable – XLPE / SHF1 – 600/1000V

These Ships Approved  SH-PC-A armoured power & control cables are siutable for shipboard use, they have a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-PC-U-F – Unarmoured Fire resisting power & control shipboard cable – Mica tape/XLPE / SHF1 – 600/1000V

These SH-PC-U-F unarmoured power & control cables offer enhanced fire resistance and are siutable for shipboard use, they have a Mica Tape +HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC-60331-21 , IEC60331-31 Fire Resistance , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-PC-A-F – Armoured Fire resisting power & control shipboard cable – Mica tape/XLPE / SHF1 – 600/1000V

These SH-PC-A-F armoured power & control cables offer enhanced fire resistance and are siutable for shipboard use, they have a Mica Tape +HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC-60331-21 , IEC60331-31 Fire Resistance , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-C-U – Control & Instrumentation , Collectively Screened Unarmoured shipboard cable 150/250V ( 300V)

These SH-CI-C-U unarmoured cables are designed for control and instrumentation applications on board ships and offer a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-C-A – Control & Instrumentation , Collectively Screened Armoured shipboard cable 150/250V ( 300V)

These SH-CI-C-A amoured cables are designed for control and instrumentation applications on board ships and offer a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-C-U-F – Control & Instrumentation , Collectively Screened Unarmoured Fire Resisting cable 150/250V ( 300V)

These SH-CI-C-U-F unamoured fire resisting cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-C-A-F – Control & Instrumentation , Collectively Screened Armoured Fire Resisting cable 150/250V ( 300V)

These SH-CI-C-A-F unamoured fire resisting cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-I-U – Control & Instrumentation , Individually Screened Unarmoured shipboard cable 150/250V ( 300V)

These SH-CI-I-U unarmoured cables are designed for control and instrumentation applications on board ships and offer a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-I-A – Control & Instrumentation , Individually Screened Armoured shipboard cable 150/250V ( 300V)

These SH-CI-I-A armoured cables are designed for control and instrumentation applications on board ships and offer a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-I-U-F – Control & Instrumentation , Individually Screened Unarmoured Fire Resisting cable 150/250V ( 300V)

These SH-CI-I-U-F unamoured fire resisting individually screened cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-I-A-F – Control & Instrumentation , Individually Screened Armoured Fire Resisting cable 150/250V ( 300V)

These SH-CI-I-U-F amoured fire resisting individually screened cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-IC-U – Control & Instrumentation , Individually & Collectively Screened Unarmoured shipboard cable 150/250V

These SH-CI-IC-U unarmoured individually & collectively screened cables are designed for control and instrumentation applications on board ships and offer a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-IC-A – Control & Instrumentation , Individually & Collectively Screened Armoured shipboard cable 150/250V

These SH-CI-IC-A armoured individually & collectively screened cables are designed for control and instrumentation applications on board ships and offer a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-IC-U-F -Control & Instrumentation Individually & Collectively Screened Unarmoured Fire Resisting cable 150/250V

These SH-CI-I-U-F unamoured fire resisting individually & collectively screened cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-IC-A-F -Control & Instrumentation Individually & Collectively Screened Armoured Fire Resisting cable 150/250V

These SH-CI-I-A-F amoured fire resisting individually & collectively screened cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-U-U -Control & Instrumentation Unscreened & Unarmoured shipboard cable 150/250V (300V)

These SH-CI-U-U unarmoured power & control cables are siutable for shipboard use, they have a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-U-A -Control & Instrumentation Unscreened & Armoured shipboard cable 150/250V (300V)

These SH-CI-U-A armoured power & control cables are siutable for shipboard use, they have a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-U-U-F -Control & Instrumentation Unscreened & Unarmoured Fire Resisting cable 150/250V (300V)

These SH-CI-U-U-F unamoured fire resisting cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-CI-U-A-F -Control & Instrumentation Unscreened & Armoured Fire Resisting cable 150/250V (300V)

These SH-CI-U-A-F unamoured fire resisting cables are designed for control and instrumentation applications on board ships and offer a Mica Tape / HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2, IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. IEC 60331-21, IEC60331-31 Fire resistance. Cables have Rina , ABS , Llyods and Veritas approvals.

SH-ICC -Control / Comms & Instrumentation Screened & Unarmoured cable – 60V

These SH-ICC unarmoured communication & control cables are siutable for shipboard use, they have a HF XLPE insulation material and a SHF-1 sheath compound. These cables conform to IEC 60332-3-22 , IEC60332-1-2 , IEC60754-1, IEC60754-2 , IEC60684-2 , IEC61034-1 , IEC61034-2. Cables have Rina , ABS , Llyods and Veritas approvals.

SHIP Drive – Screened Drag chain motor supply cables for shipboard applications 600/1000V

This Ship Drive cable is design for drag chain / high flexing shipboard cable applications . It is Oil & sunlight resistant , has enhanced oil resistance according to IEC 6092-350 AnnexF & Low temp behaviour at -40 according to IEC60092-350 annex E ,in addition it conforms to IEC60322-1-2 not flame propagation and IEC 60754-1 Halogen content and has Llyods Register approval.

Drag Chain / High flex Shipboard Cables

SHIP Drive BR- Screened Drag chain motor supply cables for shipboard applications 600/1000V

This Ship Drive BR cable is design for drag chain / high flexing shipboard cable applications . It is Oil & sunlight resistant , has enhanced oil resistance according to IEC 6092-350 AnnexF & Low temp behaviour at -40 according to IEC60092-350 annex E ,in addition it conforms to IEC60322-1-2 not flame propagation and IEC 60754-1 Halogen content and has Llyods Register approval.

SHIP Feedback- Screened Drag chain control cables for shipboard applications 300/500V & 600/1000V

This Ship Feedback cable is design for drag chain / high flexing shipboard cable applications . It is Oil & sunlight resistant , has enhanced oil resistance according to IEC 6092-350 AnnexF & Low temp behaviour at -40 according to IEC60092-350 annex E ,in addition it conforms to IEC60322-1-2 not flame propagation and IEC 60754-1 Halogen content and has Llyods Register approval.